Echolight Bakersfield

Studies

Fragility Score (FS): a REMS‑based indicator for the prediction of incident fragility fractures at 5 years

Paola Pisani1, et al

Results: Concerning the prediction of generic osteoporotic fractures, FS provided AUC=0.811 for women and AUC=0.780 for men, which resulted in AUC=0.715 and AUC=0.758, respectively, when adjusted for age and body mass index (BMI). For the prediction of hip fractures, the corresponding values were AUC=0.780 for women and AUC=0.809 for men, which became AUC=0.735 and AUC=0.758, respectively, after age- and BMI-adjustment. Overall, FS showed the highest prediction ability for any considered fracture type in both genders, resulting always being significantly higher than either T-scores, whose AUC values were in the range 0.472–0.709.

Conclusion: Fragility Score (FS) displayed a superior performance in fracture prediction, representing a valuable diagnostic tool to accurately detect a short-term fracture risk.

Aging Clinical and Experimental Research
https://doi.org/10.1007/s40520-023-02358-2

Radiofrequency Echographic Multi Spectrometry (R.E.M.S.): New Frontiers for Ultrasound Use in the Assessment of Bone Status—A Current Picture

Antonella Al Refaie, et al

Abstract: Osteoporosis is a frequently occurring skeletal disease, and osteoporosis-related fractures represent a significant burden for healthcare systems. Dual-Energy X-ray Absorptiometry (DXA) is the most commonly used method for assessing bone mineral density (BMD). Today, particular attention is being directed towards new technologies, especially those that do not use radiation, for the early diagnosis of altered bone status. Radiofrequency Echographic Multi Spectrometry (REMS)is a non-ionizing technology that evaluates the bone status at axial skeletal sites by analyzing raw ultrasound signals. 

In this review, we evaluated the data on the REMS technique present in the literature. The literature data confirmed diagnostic concordance between BMD values obtained using DXA and REMS. Furthermore, REMS has adequate precision and repeatability characteristics, is able to predict the risk of fragility fractures, and may be able to overcome some of the limitations of DXA.

In conclusion, REMS could become the method of choice for the assessment of bone status in children, in women of childbearing age or who are pregnant, and in several secondary osteoporosis conditions due to its good precision and replicability, its transportability, and the absence of ionizing radiation. Finally, REMS may allow qualitative and not just quantitative assessments of bone status. 

Diagnostics 2023, 13, 1666. https://doi.org/10.3390/diagnostics13101666 

Radiofrequency Echographic Multi Spectrometry (REMS) for the diagnosis of osteoporosis in a European multicenter clinical context

Bernard Cortet, et al

Results: Overall, 4245 lumbar spine scans and 4271 femoral neck scans were performed. The ability to discriminate patients with and without osteoporosis by femoral neck investigation resulted in sensitivity and specificity of 90.4% and 95.5%, respectively. For lumbar spine scans, a sensitivity of 90.9% and a specificity of 95.1% were obtained. The areas under the curve (AUCs) of the Receiver Operating Characteristic (ROC) curve evaluating the ability to discriminate groups of patients with previous osteoporotic fracture using DXA and REMS T-score values were 0.631 and 0.683 (p < 0.0001), respectively, for femoral neck scans, whereas 0.603 and 0.640 (p = 0.0002), respectively, for lumbar spine scans. 

Conclusion: The diagnostic effectiveness of REMS technology at reference anatomical sites for the assessment of osteoporosis has been confirmed in a large series of female patients, spanning from younger and pre-menopausal
to elderly women up to 90 years, in a multicenter European clinical context. 

https://doi.org/10.1016/j.bone.2020.115786

Radiofrequency Echographic Multi Spectrometry (REMS) in the diagnosis and management of osteoporosis: state of the art

Nicholas R Fuggle, et al

Abstract

Radiofrequency Echographic Multi Spectrometry (REMS) is a radiation-free, portable technology, which can be used for the assessment and monitoring of osteoporosis at the lumbar spine and femoral neck and may facilitate wider access to axial BMD measurement compared with standard dual-energy x-ray absorptiometry (DXA).There is a growing literature demonstrating a strong correlation between DXA and REMS measures of BMD and further work supporting 5-year prediction of fracture using the REMS Fragility Score, which provides a measure of bone quality (in addition to the quantitative measure of BMD).The non-ionising radiation emitted by REMS allows it to be used in previously underserved populations including pregnant women and children and may facilitate more frequent measurement of BMD.The portability of the device means that it can be deployed to measure BMD for frail patients at the bedside (avoiding the complications in transfer and positioning which can occur with DXA), in primary care, the emergency department, low-resource settings and even at home.The current evidence base supports the technology as a useful tool in the management of osteoporosis as an alternative to DXA.

https://pubmed.ncbi.nlm.nih.gov/38904870/

Aging Clin Exp Res. 2024 Jun 21;36(1):135. doi: 10.1007/s40520-024-02784-w.

Could Radiofrequency Echographic Multi Spectrometry (REMS) overcome the overestimation in BMD by dual-energy X-ray absorptiometry (DXA) at the lumbar spine?

Carla Caffarelli, et al

Abstract

Background: Osteoarthritis (OA) and vertebral fractures at the lumbar spine lead to an overestimation of bone mineral density (BMD). Recently, a new approach for osteoporosis diagnosis, defined as radiofrequency echographic multi-spectrometry (REMS), represents an innovative diagnostic tool that seems to be able to investigate bone quality and provide an estimation of fracture risk independent of BMD. The aim of this paper was to evaluate whether the use of REMS technology can favor the diagnosis of osteoporosis in subjects with an apparent increase in BMD.

Methods: In a cohort of 159 postmenopausal (66.2 ± 11.6 yrs) women with overestimated BMD by DXA at the lumbar spine, we performed an echographic scan with the REMS technique.

Results: The mean values of BMD at different skeletal sites obtained by the DXA and REMS techniques showed that the BMD T-scores by REMS were significantly lower than those obtained by the DXA technique both at the lumbar spine (p < 0.01) and at all femoral subregions (p < 0.05). In OA subjects, the percentage of women classified as “osteoporotic” on the basis of BMD by REMS was markedly higher with respect to those classified by DXA (35.1% vs 9.3%, respectively). Similarly, the REMS allows a greater number of fractured patients to be classified as osteoporotic than DXA (58.7% vs 23.3%, respectively).

Conclusions: REMS technology by the analysis of native raw unfiltered ultrasound signals appears to be able to overcome the most common artifacts, such as OA and vertebral fracture of the lumbar spine, which affect the value of BMD by DXA.

https://pubmed.ncbi.nlm.nih.gov/35590362/

Radiofrequency echographic multispectrometry compared with dual X-ray absorptiometry for osteoporosis diagnosis on lumbar spine and femoral neck

M Di Paola, et al

Abstract

An innovative, non-ionizing technique to diagnose osteoporosis on lumbar spine and femoral neck was evaluated through a multicenter study involving 1914 women. The proposed method showed significant agreement with reference gold standard method and, therefore, a potential for early osteoporosis diagnoses and possibly improved patient management.

Introduction: To assess precision (i.e., short term intra-operator precision) and diagnostic accuracy of an innovative non-ionizing technique, REMS (Radiofrequency Echographic Multi Spectrometry), in comparison with the clinical gold standard reference DXA (dual X-ray absorptiometry), through an observational multicenter clinical study.

Methods: In a multicenter cross-sectional observational study, a total of 1914 postmenopausal women (51-70 years) underwent spinal (n = 1553) and/or femoral (n = 1637) DXA, according to their medical prescription, and echographic scan of the same anatomical sites performed with the REMS approach. All the medical reports (DXA and REMS) were carefully checked to identify possible errors that could have caused inaccurate measurements: erroneous REMS reports were excluded, whereas erroneous DXA reports were re-analyzed where possible and otherwise excluded before assessing REMS accuracy. REMS precision was independently assessed.

Results: In the spinal group, quality assessment on medical reports produced the exclusion of 280 patients because of REMS errors and 78 patients because of DXA errors, whereas 296 DXA reports were re-analyzed and corrected. Analogously, in the femoral group there were 205 exclusions for REMS errors, 59 exclusions for DXA errors, and 217 re-analyzed DXA reports. In the resulting dataset (n = 1195 for spine, n = 1373 for femur) REMS outcome showed a good agreement with DXA: the average difference in bone mineral density (BMD, bias ± 2SD) was -0.004 ± 0.088 g/cm2 for spine and – 0.006 ± 0.076 g/cm2 for femur. Linear regression showed also that the two methods were well correlated: standard error of the estimate (SEE) was 5.3% for spine and 5.8% for femur. REMS precision, expressed as RMS-CV, was 0.38% for spine and 0.32% for femur.

Conclusions: The REMS approach can be used for non-ionizing osteoporosis diagnosis directly on lumbar spine and femoral neck with a good level of accuracy and precision. However, a more rigorous operator training is needed to limit the erroneous acquisitions and to ensure the full clinical practicability.

 

https://pubmed.ncbi.nlm.nih.gov/30178159/

Fragility Score (FS): a REMS‑based indicator for the prediction of incident fragility fractures at 5 years

Paola Pisani1, et al

Results: Concerning the prediction of generic osteoporotic fractures, FS provided AUC=0.811 for women and AUC=0.780 for men, which resulted in AUC=0.715 and AUC=0.758, respectively, when adjusted for age and body mass index (BMI). For the prediction of hip fractures, the corresponding values were AUC=0.780 for women and AUC=0.809 for men, which became AUC=0.735 and AUC=0.758, respectively, after age- and BMI-adjustment. Overall, FS showed the highest prediction ability for any considered fracture type in both genders, resulting always being significantly higher than either T-scores, whose AUC values were in the range 0.472–0.709.

Conclusion: Fragility Score (FS) displayed a superior performance in fracture prediction, representing a valuable diagnostic tool to accurately detect a short-term fracture risk.

Aging Clinical and Experimental Research

https://link.springer.com/article/10.1007/s40520-023-02358-2

Radiofrequency Echographic Multi Spectrometry (R.E.M.S.): New Frontiers for Ultrasound Use in the Assessment of Bone Status—A Current Picture

Antonella Al Refaie, et al

Abstract: Osteoporosis is a frequently occurring skeletal disease, and osteoporosis-related fractures represent a significant burden for healthcare systems. Dual-Energy X-ray Absorptiometry (DXA) is the most commonly used method for assessing bone mineral density (BMD). Today, particular attention is being directed towards new technologies, especially those that do not use radiation, for the early diagnosis of altered bone status. Radiofrequency Echographic Multi Spectrometry (REMS)is a non-ionizing technology that evaluates the bone status at axial skeletal sites by analyzing raw ultrasound signals.

In this review, we evaluated the data on the REMS technique present in the literature. The literature data confirmed diagnostic concordance between BMD values obtained using DXA and REMS. Furthermore, REMS has adequate precision and repeatability characteristics, is able to predict the risk of fragility fractures, and may be able to overcome some of the limitations of DXA.

Radiofrequency Echographic Multi Spectrometry (R.E.M.S.): New Frontiers for Ultrasound Use in the Assessment of Bone Status—A Current Picture
Antonella Al Refaie, et al

Abstract: Osteoporosis is a frequently occurring skeletal disease, and osteoporosis-related fractures represent a significant burden for healthcare systems. Dual-Energy X-ray Absorptiometry (DXA) is the most commonly used method for assessing bone mineral density (BMD). Today, particular attention is being directed towards new technologies, especially those that do not use radiation, for the early diagnosis of altered bone status. Radiofrequency Echographic Multi Spectrometry (REMS)is a non-ionizing technology that evaluates the bone status at axial skeletal sites by analyzing raw ultrasound signals.

In this review, we evaluated the data on the REMS technique present in the literature. The literature data confirmed diagnostic concordance between BMD values obtained using DXA and REMS. Furthermore, REMS has adequate precision and repeatability characteristics, is able to predict the risk of fragility fractures, and may be able to overcome some of the limitations of DXA.

In conclusion, REMS could become the method of choice for the assessment of bone status in children, in women of childbearing age or who are pregnant, and in several secondary osteoporosis conditions due to its good precision and replicability, its transportability, and the absence of ionizing radiation. Finally, REMS may allow qualitative and not just quantitative assessments of bone status.

Diagnostics 2023, 13, 1666.

https://doi.org/10.3390/diagnostics13101666

Radiofrequency Echographic Multi Spectrometry (REMS) for the diagnosis of osteoporosis in a European multicenter clinical context

Bernard Cortet, et al

Results: Overall, 4245 lumbar spine scans and 4271 femoral neck scans were performed. The ability to discriminate patients with and without osteoporosis by femoral neck investigation resulted in sensitivity and specificity of 90.4% and 95.5%, respectively. For lumbar spine scans, a sensitivity of 90.9% and a specificity of 95.1% were obtained. The areas under the curve (AUCs) of the Receiver Operating Characteristic (ROC) curve evaluating the ability to discriminate groups of patients with previous osteoporotic fracture using DXA and REMS T-score values were 0.631 and 0.683 (p < 0.0001), respectively, for femoral neck scans, whereas 0.603 and 0.640 (p = 0.0002), respectively, for lumbar spine scans.

Conclusion: The diagnostic effectiveness of REMS technology at reference anatomical sites for the assessment of osteoporosis has been confirmed in a large series of female patients, spanning from younger and pre-menopausal

to elderly women up to 90 years, in a multicenter European clinical context.

https://doi.org/10.1016/j.bone.2020.115786

Radiofrequency Echographic Multi Spectrometry (REMS) in the diagnosis and management of osteoporosis: state of the art

Abstract

Radiofrequency Echographic Multi Spectrometry (REMS) is a radiation-free, portable technology, which can be used for the assessment and monitoring of osteoporosis at the lumbar spine and femoral neck and may facilitate wider access to axial BMD measurement compared with standard dual-energy x-ray absorptiometry (DXA).There is a growing literature demonstrating a strong correlation between DXA and REMS measures of BMD and further work supporting 5-year prediction of fracture using the REMS Fragility Score, which provides a measure of bone quality (in addition to the quantitative measure of BMD).The non-ionising radiation emitted by REMS allows it to be used in previously underserved populations including pregnant women and children and may facilitate more frequent measurement of BMD.The portability of the device means that it can be deployed to measure BMD for frail patients at the bedside (avoiding the complications in transfer and positioning which can occur with DXA), in primary care, the emergency department, low-resource settings and even at home.The current evidence base supports the technology as a useful tool in the management of osteoporosis as an alternative to DXA.

https://pubmed.ncbi.nlm.nih.gov/38904870/

Aging Clin Exp Res. 2024 Jun 21;36(1):135. doi: 10.1007/s40520-024-02784-w.

Could Radiofrequency Echographic Multi Spectrometry (REMS) overcome the overestimation in BMD by dual-energy X-ray absorptiometry (DXA) at the lumbar spine?

Carla Caffarelli, et al

Abstract

Background: Osteoarthritis (OA) and vertebral fractures at the lumbar spine lead to an overestimation of bone mineral density (BMD). Recently, a new approach for osteoporosis diagnosis, defined as radiofrequency echographic multi-spectrometry (REMS), represents an innovative diagnostic tool that seems to be able to investigate bone quality and provide an estimation of fracture risk independent of BMD. The aim of this paper was to evaluate whether the use of REMS technology can favor the diagnosis of osteoporosis in subjects with an apparent increase in BMD.

Methods: In a cohort of 159 postmenopausal (66.2 ± 11.6 yrs) women with overestimated BMD by DXA at the lumbar spine, we performed an echographic scan with the REMS technique.

Results: The mean values of BMD at different skeletal sites obtained by the DXA and REMS techniques showed that the BMD T-scores by REMS were significantly lower than those obtained by the DXA technique both at the lumbar spine (p < 0.01) and at all femoral subregions (p < 0.05). In OA subjects, the percentage of women classified as “osteoporotic” on the basis of BMD by REMS was markedly higher with respect to those classified by DXA (35.1% vs 9.3%, respectively). Similarly, the REMS allows a greater number of fractured patients to be classified as osteoporotic than DXA (58.7% vs 23.3%, respectively).

Conclusions: REMS technology by the analysis of native raw unfiltered ultrasound signals appears to be able to overcome the most common artifacts, such as OA and vertebral fracture of the lumbar spine, which affect the value of BMD by DXA.

https://pubmed.ncbi.nlm.nih.gov/35590362/

Radiofrequency echographic multispectrometry compared with dual X-ray absorptiometry for osteoporosis diagnosis on lumbar spine and femoral neck

M Di Paola, et al

Abstract

An innovative, non-ionizing technique to diagnose osteoporosis on lumbar spine and femoral neck was evaluated through a multicenter study involving 1914 women. The proposed method showed significant agreement with reference gold standard method and, therefore, a potential for early osteoporosis diagnoses and possibly improved patient management.

Introduction: To assess precision (i.e., short term intra-operator precision) and diagnostic accuracy of an innovative non-ionizing technique, REMS (Radiofrequency Echographic Multi Spectrometry), in comparison with the clinical gold standard reference DXA (dual X-ray absorptiometry), through an observational multicenter clinical study.

Methods: In a multicenter cross-sectional observational study, a total of 1914 postmenopausal women (51-70 years) underwent spinal (n = 1553) and/or femoral (n = 1637) DXA, according to their medical prescription, and echographic scan of the same anatomical sites performed with the REMS approach. All the medical reports (DXA and REMS) were carefully checked to identify possible errors that could have caused inaccurate measurements: erroneous REMS reports were excluded, whereas erroneous DXA reports were re-analyzed where possible and otherwise excluded before assessing REMS accuracy. REMS precision was independently assessed.

Results: In the spinal group, quality assessment on medical reports produced the exclusion of 280 patients because of REMS errors and 78 patients because of DXA errors, whereas 296 DXA reports were re-analyzed and corrected. Analogously, in the femoral group there were 205 exclusions for REMS errors, 59 exclusions for DXA errors, and 217 re-analyzed DXA reports. In the resulting dataset (n = 1195 for spine, n = 1373 for femur) REMS outcome showed a good agreement with DXA: the average difference in bone mineral density (BMD, bias ± 2SD) was -0.004 ± 0.088 g/cm2 for spine and – 0.006 ± 0.076 g/cm2 for femur. Linear regression showed also that the two methods were well correlated: standard error of the estimate (SEE) was 5.3% for spine and 5.8% for femur. REMS precision, expressed as RMS-CV, was 0.38% for spine and 0.32% for femur.

Conclusions: The REMS approach can be used for non-ionizing osteoporosis diagnosis directly on lumbar spine and femoral neck with a good level of accuracy and precision. However, a more rigorous operator training is needed to limit the erroneous acquisitions and to ensure the full clinical practicability.

Scroll to Top